Pan-Coronavirus Panel

This panel supports characterization and genomic surveillance of 225 known and novel coronaviruses from humans and animal reservoirs.

< 9 hr library prep time

Assay time

< 2 hr library prep time

Hands-on time

10-100 ng

Input quantity

See full details in the specifications table

Overview

The Pan-Coronavirus Panel (Pan-CoV) allows for detection and sequencing of known human and animal coronaviruses and closely related novel coronaviruses with the potential to become infectious to humans. It includes hybrid–capture oligos that span across reference genomes of multiple coronavirus strains and various known animal hosts. 

When combined with Illumina RNA Prep with Enrichment, the Pan-Coronavirus Panel enables whole-genome sequencing (WGS) of 225 known human and animal coronaviruses. The targeted enrichment approach captures mutations and variants throughout the viral genome, enabling sequencing of novel coronavirus strains and detection of recombination between strains. 

The panel can be used for multiple applications, including:

  • Surveillance to identify and monitor coronaviruses in animal hosts

  • Track transmission patterns and viral mutations

  • Guide vaccine and therapeutic developments

Integrated viral sequencing solution

The Pan-Coronavirus Panel can integrate into a comprehensive workflow that includes library preparation, target enrichment, next-generation sequencing (NGS), and powerful data analysis, providing a simple means to obtain robust and reliable viral results.


Specifications


Required products

Illumina RNA Prep with Enrichment, (L) Tagmentation (16 or 96 Samples) needs to be ordered separately as well as index adapters. Illumina DNA/RNA Indexes Set A, B, C, or D can be used.

We recommend ordering the Illumina DNA/RNA UD Indexes Sets A-D (20091654, 20091656, 20091658, 20091660) since the IDT for Illumina DNA/RNA UD Indexes Sets A-D (20027213, 20027214,20042666, 20042667) are being discontinued.

 

/ Results

Applications

Target enrichment through hybrid–capture allows for detection and sequencing of 225 known human and animal coronaviruses and closely related novel coronaviruses for surveillance of animal reservoirs, tracking transmissions, and therapeutic and vaccine development.

Example workflow


Project recommendations

Instrument Recommended number of samples Read length
MiSeq System

6–12 samples using MiSeq Reagent Kit v2 (1–2M reads/sample) 

2 × 150 bp

NextSeq 550 System

65–130 samples using NextSeq 500/550 Mid-Output Kit (1–2M reads/sample)

2 × 150 bp

NextSeq 1000 System

100–200 samples using P2 Reagent Kit (1–2M reads/sample)

2 × 150 bp

NextSeq 2000 System

100–200 samples using P2 Reagent Kit (1–2M reads/sample)

2 × 150 bp


Related applications and methods

Documentation

Product literature

Compare

Pan-Coronavirus Panel Viral Surveillance Panel Illumina Respiratory Virus Enrichment Kit
Assay time < 9 hr library prep time < 9 hr library prep time < 9 hr library prep time
Automation capability Liquid handling robots Liquid handling robots Liquid handling robots
Description The Pan-Coronavirus Panel is part of an integrated workflow that allows for the detection and whole-genome sequencing of over 200 known and novel coronavirus strains in various animal hosts. The Viral Surveillance Panel v2 Kit provides an optimized workflow that supports viral outbreak detection and monitoring of more than 200 RNA and DNA viral pathogens. A streamlined workflow for detecting and analyzing SARS-CoV-2 and other common respiratory viruses. The agnostic design allows for widespread identification of pathogenic viruses across multiple sample types of interest.
Hands-on time < 2 hr library prep time < 2 hr library prep time < 2 hr library prep time
Input quantity 10-100 ng 10-100 ng 10-100 ng
Instruments MiSeq System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiniSeq System MiSeq System, iSeq 100 System, NextSeq 550 System, NextSeq 2000 System, NextSeq 1000 System, MiniSeq System MiSeq System, NextSeq 550 System, NextSeq 2000 System, MiniSeq System
Mechanism of action On-bead tagmentation followed by a single hybridization step On-bead tagmentation followed by a single hybridization step On-bead tagmentation followed by a single hybridization step
Method Whole-genome sequencing, Target enrichment Targeted DNA sequencing, Whole-genome sequencing, Targeted RNA sequencing, Target enrichment Targeted DNA sequencing, Targeted RNA sequencing, Target enrichment
Multiplexing Up to 384 samples in a single run with unique dual indexes Up to 384 samples in a single run with unique dual indexes Up to 384 samples in a single run with unique dual indexes
Nucleic acid type RNA DNA, RNA DNA, RNA
Species category Virus Virus Human, Virus
Strand specificity Non-stranded Non-stranded
Technology Sequencing Sequencing Sequencing

Selection tools:

Figures

Coronavirus strains covered in panel

Pan-Coronavirus Panel includes hybrid–capture oligos that capture 225 known human and animal coronaviruses.

Host-associated coronavirus genomes

Pan-Coronavirus Panel includes various known animal hosts.

Enrichment of Coronaviridae reads

The Pan-Coronavirus Panel successfully enriched Coronaviridae reads in all libraries tested across a range of viral copy number input.

Improved coronavirus genome coverage

Median coverage of synthetic viral RNA controls (SARS-CoV-2 and HCoV229E) in 10 ng UHR after enrichment with the Pan-Coronavirus Panel. Increased read depth (top) and read length (bottom) resulted in improved genome coverage. Read lengths were trimmed to 36, 74, 100, and 149 bp.

Panel (1)

Pan-Coronavirus Panel, RUO 96 Rxns

20088155

Includes Viral Surveillance Panel sufficient for 32, 3-plex enrichment reactions when paired with Illumina RNA Prep with Enrichment kit. Purchase library prep and enrichment kit and index adapters separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Library prep (2)

Illumina® RNA Prep with Enrichment, (L) Tagmentation (16 Samples)

20040536

Includes reagents for preparing and enriching 16 libraries (16, 1-plex enrichment reactions). Purchase enrichment probe panel, Purification Beads and index adapters separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Illumina® RNA Prep with Enrichment, (L) Tagmentation (96 Samples)

20040537

Includes reagents for preparing and enriching 96 libraries (32, 3-plex enrichment reactions). Purchase enrichment probe panel, Purification Beads and index adapters separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Index adapters (8)

Illumina® DNA/RNA UD Indexes Set A, Tagmentation (96 Indexes, 96 Samples)

20091654

Illumina® DNA/RNA UD Indexes Set A, Tagmentation (96 Indexes, 96 Samples) Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Illumina® DNA/RNA UD Indexes Set B, Tagmentation (96 Indexes, 96 Samples)

20091656

Illumina® DNA/RNA UD Indexes Set B, Tagmentation (96 Indexes, 96 Samples) Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Illumina® DNA/RNA UD Indexes Set C, Tagmentation (96 Indexes, 96 Samples)

20091658

Illumina® DNA/RNA UD Indexes Set C, Tagmentation (96 Indexes, 96 Samples) Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Illumina® DNA/RNA UD Indexes Set D, Tagmentation (96 Indexes, 96 Samples)

20091660

Illumina® DNA/RNA UD Indexes Set D, Tagmentation (96 Indexes, 96 Samples) Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

IDT® for Illumina® DNA/RNA UD Indexes Set A, Tagmentation (96 Indexes, 96 Samples)

20027213

Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

IDT® for Illumina® DNA/RNA UD Indexes Set B, Tagmentation (96 Indexes, 96 Samples)

20027214

Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

IDT® for Illumina® DNA/RNA UD Indexes Set C, Tagmentation (96 Indexes, 96 Samples)

20042666

Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

IDT® for Illumina® DNA/RNA UD Indexes Set D, Tagmentation (96 Indexes, 96 Samples)

20042667

Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.

Sign in to add to cart or see pricing.

List Price:

Discounts:

Showing of

Selection summary

Product

Qty

Unit Price

FAQs

The panel is built with enrichment probes that allows for most variants to be captured effectively. In addition, the Pan-Coronavirus Panel was designed to enrich for 225 coronavirus genotypes from various animal sources and expected to capture most novel coronaviruses. For example, the Pan-Coronavirus Panel was designed before the Omicron variant but was still shown to enrich for the entire genome with high coverage (see data sheet for details).

Yes, the Pan-Coronavirus Panel was designed to work on environmental samples and samples from various animal sources. In fact, the panel is to be used for sequencing of coronviruses from diverse sample types such as bats, wastewater, and any potential coronavirus host. To maximize success with the panels, use the highest quality RNA you can obtain.

There is a free DRAGEN Microbial Enrichment BaseSpace App that can assemble contigs and explore genome coverage/depth, in addition to other outputs.

/ Results

Order the NovaSeq X Series

Advanced chemistry, optics, and informatics combine to deliver exceptional speed and data quality, outstanding throughput and scalability.

MiSeq Reagent Kit v3

Optimized reagent kit that provides increased cluster density and read length, improving sequencing quality scores compared to earlier versions.

TruSight Oncology 500

Enable CGP with a large pan-cancer panel covering all major variant classes plus gene signatures (TMB, MSI, and HRD) from FFPE tissue.

Illumina DNA Prep

A fast, integrated workflow for preparing libraries for use in a wide range of sequencing applications.

Speak with a specialist

Reach out for information about our products and services, or get answers to questions about our technology.